После того как вы нашли ошибку выдаваемою вашим мфу или принтером, лучше обратиться в сервисный центр. Как правило без сервисного инженера вам будет сложно, а зачастую невозможно устранить ошибку.

Наш сервисный центр работает для Москвы и М.О. в случае с другими регионами рекомендуем обратиться в местные сервисные центры.

Телефон сервисной службы: +7 (495) 208-47-48

Вопросы ?Отправьте быструю заявку
Ошибки Kyocera ECOSYS P4040dn
  • Code: 0100
  • Description: Backup memory device error
  • Remedy: Defective flash memory. Replace the main PWB and check for correct operation .
    Defective main PWB.
  • Code: 0120
  • Description: MAC address data error For data in which the MAC address is invalid.
  • Remedy: Defective flash memory. Replace the main PWB and check for correct operation .
    Defective main PWB. Replace the main PWB and check for correct operation .
  • Code: 0130
  • Description: Backup memory read/write error (main PWB)
  • Remedy: Defective flash memory. Defective main PWB. Replace the main PWB and check for correct operation .
  • Code: 0140
  • Description: Backup memory data error (main PWB)
  • Remedy: Defective flash memory. Defective main PWB. Replace the main PWB and check for correct operation.
  • Code: 0150
  • Description: Backup memory read/write error (engine PWB) Detecting engine PWB EEPROM communication error.
  • Remedy: Improper installation engine PWB EEPROM. Check the installation of the EEPROM and remedy if necessary.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
    Device damage of EEPROM. Contact the Service Administrative Division.
  • Code: 0160
  • Description: Backup memory data error (engine PWB)
  • Remedy: Defective EEPROM. Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 0170
  • Description: Billing counting error A checksum error is detected in the main and engine backup memories for the billing counters.
  • Remedy: Data damage of EEPROM. Contact the Service Administrative Division.
    Defective PWB. Replace the main PWB or the engine PWB and check for correct operation.
  • Code: 0190
  • Description: Backup memory device error (engine PWB)
  • Remedy: Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 0800
  • Description: Image processing error JAM010x and JAM21 are detected twice.
  • Remedy: Defective main PWB. Replace the main PWB and check for correct operations page 1-5-38).
  • Code: 0840
  • Description: Faults of RTC The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
  • Remedy: The battery is disconnected from the main PWB. Check visually and remedy if necessary
    Defective main PWB. Replace the main PWB and check for correct operation.
  • Code: 1010
  • Description: Lift motor error After cassette 1 is inserted, lift sensor does not turn on within 10 s. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Lift motor and engine PWB (YC13)
    Defective drive transmission system of the lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective lift motor. Replace the lift motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 1020
  • Description: PF lift motor 1 error (paper feeder) After cassette 2 is inserted, PF lift sensor 1 does not turn on. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 1 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 1.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1030
  • Description: PF lift motor 2 error (paper feeder) After cassette 3 is inserted, PF lift sensor 2 does not turn on. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 2 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 2.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1040
  • Description: PF lift motor 3 error (paper feeder) After cassette 4 is inserted, PF lift sensor 3 does not turn on. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 3 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 3.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1050
  • Description: PF lift motor 4 error (paper feeder) After cassette 5 is inserted, PF lift sensor 4 does not turn on. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 4 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 4.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1800
  • Description: Paper feeder 1 communication error A communication error is detected 10 times in succession.
  • Remedy: Improper installation paper feeder. Follow installation instruction carefully again.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF main PWB (YC3) and engine PWB (YC22)
    Defective engine PWB. Replace the engine PWB and check for correct operation.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1810
  • Description: Paper feeder 2 communication error A communication error is detected 10 times in succession.
  • Remedy: Improper installation paper feeder. Follow installation instruction carefully again.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF main PWB (YC3) and PF main PWB (YC4)
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1820
  • Description: Paper feeder 3 communication error A communication error is detected 10 times in succession.
  • Remedy: Improper installation paper feeder. Follow installation instruction carefully again.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF main PWB (YC3) and PF main PWB (YC4)
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1830
  • Description: Paper feeder 4 communication error A communication error is detected 10 times in succession.
  • Remedy: Improper installation paper feeder. Follow installation instruction carefully again.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF main PWB (YC3) and PF main PWB (YC4)
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1900
  • Description: Paper feeder 1 EEPROM error When writing the data, the write data and the read data is not in agreement.
  • Remedy: Defective PF main PWB. Device damage of EEPROM. Replace the PF main PWB.
  • Code: 1910
  • Description: Paper feeder 2 EEPROM error When writing the data, the write data and the read data is not in agreement.
  • Remedy: Defective PF main PWB. Replace the PF main PWB.
    Device damage of EEPROM. Replace the PF main PWB.
  • Code: 1920
  • Description: Paper feeder 3 EEPROM error When writing the data, the write data and the read data is not in agreement.
  • Remedy: Defective PF main PWB. Replace the PF main PWB.
    Device damage of EEPROM. Replace the PF main PWB.
  • Code: 1930
  • Description: Paper feeder 4 EEPROM error When writing the data, the write data and the read data is not in agreement.
  • Remedy: Defective PF main PWB. Replace the PF main PWB.
    Device damage of EEPROM. Replace the PF main PWB.
  • Code: 2000
  • Description: Main motor drive error The main motor is not stabilized within 4 s after driving starts.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Main motor and engine PWB (YC4)
    Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective main motor. Replace the main motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 2010
  • Description: Main motor steady-state error Stable OFF is detected for 4 s continuously after main motor stabilized.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Main motor and engine PWB (YC4)
    Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective main motor. Replace the main motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 2200
  • Description: Drum motor drive error The drum motor is not stabilized within 4 s after driving starts.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum motor and engine PWB (YC4)
    Defective drive transmission system of the drum motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective drum motor. Replace the drum motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 2210
  • Description: Drum motor steady-state error Stable OFF is detected for 4 s continuously after drum motor stabilized.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum motor and engine PWB (YC4)
    Defective drive transmission system of the drum motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective drum motor. Replace the drum motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 2330
  • Description: Fuser pressure release motor error (Over-current) The over-current detection signal of the motor is detected continuously twenty times.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser pressure release motor and relay-L PWB(YC11) Relay-L PWB and engine PWB(YC2)
    Defective drive transmission system of the fuser pressure release motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective fuser pressure release motor. Replace the fuser pressure release motor.
    Defective PWB. Replace the relay-L PWB or engine PWB.
  • Code: 2340
  • Description: Fuser pressure release motor error (Timeout) The position detection sensor is not detected continuously for 30 s.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser pressure release motor and relay-L PWB(YC11) Relay-L PWB and engine PWB(YC2)
    Defective drive transmission system of the fuser pressure release motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective fuser pressure release motor. Replace the fuser pressure release motor.
    Defective PWB. Replace the relay-L PWB or engine PWB.
  • Code: 2600
  • Description: PF drive motor 1 error (paper feeder 1) When the PF drive motor is driven, error signal is detected continuously for 5 s.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 1 and PF main PWB (YC6)
    Defective drive transmission system of the PF drive motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF drive motor. Replace the PF drive motor 1.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 2610
  • Description: PF drive motor 2 error (paper feeder 2) When the PF drive motor is driven, error signal is detected continuously for 5 s.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 2 and PF main PWB (YC6)
    Defective drive transmission system of the PF drive motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF drive motor. Replace the PF drive motor 2.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 2620
  • Description: PF drive motor 3 error (paper feeder 3) When the PF drive motor is driven, error signal is detected continuously for 5 s.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 3 and PF main PWB (YC6)
    Defective drive transmission system of the PF drive motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF drive motor. Replace the PF drive motor 3.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 2630
  • Description: PF drive motor 4 error (paper feeder 4) When the PF drive motor is driven, error signal is detected continuously for 5 s.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 4 and PF main PWB (YC6)
    Defective drive transmission system of the PF drive motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF drive motor. Replace the PF drive motor 4.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 4000
  • Description: Polygon motor synchronization error The polygon motor is not stabilized within 20 s after driving starts.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Polygon motor and engine PWB (YC15)
    Defective polygon motor. Replace the laser scanner unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 4200
  • Description: BD steady-state error When the value of Register BDSET is 1 after setting Register BDSET as one and passing by BD1 cycle.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PD PWB and engine PWB (YC16)
    Defective PD PWB. Replace the laser scanner unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 5100
  • Description: Chager current error When the current value measured at the time of potential adjustment is less than 20 mcA.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Chager unit and high voltage PWB High voltage PWB (YC101) and engine PWB (YC19)
    Defective high voltage PWB. Replace the high voltage PWB and check for correct operation.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 6000
  • Description: Broken fuser heater wire The detection temperature of fuser thermistor 2 is 100 °C/ 212°F or less after the fuser heater lamp has been turned on continuously for 30 s.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser heater and power source PWB (YC2) Fuser thermistor and Fuser thermistor connect PWB Fuser thermistor connect PWB and engine PWB (YC21)
    Deformed connector pin.
    Defective triac.
    Fuser thermostat triggered. Broken fuser heater wire. Reinsert the fuser unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 6020
  • Description: Abnormally high fuser thermistor 2 temperature The detection temperature of fuser thermistor 2 is higher than 235°C/455°F. In a heater-off state, the detection temperature of fuser thermistor 2 is higher than 195°C/383°F after the detection temperature of fuser thermistor 2 was 155°C/311°F or less.
  • Remedy: Deformed connector pin.
    Defective triac.
    Shorted fuser thermistor. Replace the fuser unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 6030
  • Description: Broken fuser thermistor 2 wire A/D value of the fuser thermistor 2 exceeds 1019 bit continuously for 4 s during warming up.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser thermistor and fuser thermistor connect PWB Fuser thermistor connect PWB and engine PWB (YC21)
    Deformed connector pin.
    Defective triac.
    Defective fuser thermistor. Replace the fuser unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 6120
  • Description: Abnormally high fuser thermistor 1 temperature The detection temperature of fuser thermistor 1 is higher than 245°C/473°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 195°C/383°F after the detection temperature of fuser thermistor 1 was 155°C/311°F or less.
  • Remedy: Deformed connector pin.
    Defective triac.
    Shorted fuser thermistor. Replace the fuser unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 6130
  • Description: Broken fuser thermistor 1 wire A/D value of the fuser thermistor 1 exceeds 1019 bit continuously for 4 s during warming up.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser thermistor and fuser thermistor connect PWB Fuser thermistor connect PWB and engine PWB (YC21)
    Deformed connector pin.
    Defective triac.
    Defective fuser thermistor. Replace the fuser unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 6400
  • Description: Zero-cross signal error While fuser heater control is performed, the zero-cross signal is not input within 2 s.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Power source PWB (YC3) and engine PWB (YC1)
    Defective power source PWB or engine PWB. Replace the power source PWB or the engine PWB and check for correct operation.
  • Code: 7000
  • Description: Toner motor error During driving the toner motor, an over-current detection signal is detected at intervals of 10 ms as for 300 accumulation.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Toner motor and drum PWB (YC4) Drum PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC2)
    Defective toner motor. Replace the toner motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 7100
  • Description: Toner sensor error Sensor output value of 930 or more continuously for 5 s.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Toner sensor and drum PWB (YC3) Drum PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC2)
    Defective toner sensor. Replace the developer unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 7400
  • Description: Developer unit non-installing error Sensor output value of 31 or less continuously for 5 s.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit and drum PWB (YC3) Drum PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC2)
    Defective toner sensor. Replace the developer unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 7410
  • Description: Drum unit type mismatch error The drum PWB EEPROM does not communicate normally.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit and drum connect PWB (YC1) Drum connect PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC2)
    Defective toner sensor. Replace the drum unit.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 7800
  • Description: Broken external thermistor wire The average of thermistor output value of 930 or more.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Operation PWB and engine PWB (YC17)
    Defective temperature sensor. Replace the operation PWB.
  • Code: 7810
  • Description: Short-circuited external thermistor wire The average of thermistor output value of 93 or less.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Operation PWB and engine PWB (YC17)
    Defective temperature sensor. Replace the operation PWB.
  • Code: 7900
  • Description: Drum unit EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit and drum connect PWB (YC1) Drum connect PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC15)
    Defective drum unit. Replace the drum unit.
  • Code: F000
  • Description: Main PWB — operation PWB communication error
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Operation PWB and engine PWB (YC17)
    Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
    Defective operation PWB. Replace the operation PWB and check for correct operation.
  • Code: F010
  • Description: Main PWB checksum error
  • Remedy: Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
  • Code: F020
  • Description: Main PWB RAM checksum error
  • Remedy: Defective main memory (RAM) in main PWB Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
    Defective expended memory (DIMM) Replace the expansion memory (DIMM). Also in the case of the capacity besides specification, it displays.
  • Code: F040
  • Description: Main PWB — print engine communication error
  • Remedy: Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: F050
  • Description: Print engine ROM checksum error
  • Remedy: Defective engine PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace engine PWB.
Premium WordPress Themes Download
Premium WordPress Themes Download
Download Nulled WordPress Themes
Premium WordPress Themes Download
udemy free download
download samsung firmware
Free Download WordPress Themes
download udemy paid course for free
© Все права защищены, 2024

Мы позвоним Вам по указанному номеру телефона в ближайшее время.

Нажав кнопку сделать заказ сейчас, Вы подтверждаете свое согласие на обработку персональтныйх данных
Ваша заявка принята
Мы свяжемся с вами в ближайшее время