  • Code: E-0000
  • Description: Fuser Temperature Rising Error
    Fuser Temperature does not reach 50C within 120 seconds after turning on.
  • Remedy: Error clearance 1 Have you cleared the fuser error in the Special Operation Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Special Operation Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Lamp (H1) 3 Unplug the machine, and then check the resistance of Lamp (H1) with the multimeter. Is it 15k ohm or lower? No Replace the Lamp. Thermistors (TH1 & TH2) 4 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-4, 220-5, 220-6). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 5 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Relay (RY1) 6 Select the Operation Check Mode, and then change the signal of the following signal to “H”. Device Code : 22 (Fuser Relay) And check the resistance between the following points. Between RY1-2 and RY1-4 Between RY1-6 and RY1-8 Is the each resistance almost 0 ohm? No Replace the Relay. Solid State Relay (SSR1) 7 Select the Operation Check Mode, and then change the signal of the following signals to “H”. Device Code : 22 (Fuser Relay) 21 (Fuser Lamp 1) Then check the voltage between J600 and J601. Is it 0V? CAUTION: Change the signal of “21” (Fuser Lamp 1) to “L” after checking! Yes Replace the Solid State Relay No Replace the PW11720 PCB.
  • Code: E-0001
  • Description: Fuser Over Temperature Error
    Fuser Temperature reaches over 200C.
  • Remedy: Error clearance 1 Have you cleared the fuser error in the Special Operation Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Special Operation Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Solid State Relay (SSR1) 3 Does the error occur again even if you have cleared it in the Special Operation Mode? Yes Replace the Solid State Relay. Thermistors (TH1 & TH2) 4 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor.
  • Code: E-0002
  • Description: Fuser Low Temperature Error
    1. Fuser Temperature at the time of turning on was 50 to 100C, but it does not rise up to 120C within 150 seconds after that.
    2. Fuser Temperature at the time of turning on was higher than 100C, but it does not rise up to the setting temperature within 270 seconds after that.
  • Remedy: Error clearance 1 Have you cleared the fuser error in the Special Operation Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Special Operation Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Lamp (H1) 3 Unplug the machine, and then check the resistance of Lamp (H1) with the multimeter. Is it 15k ohm or lower? No Replace the Lamp. Thermistors (TH1 & TH2) 4 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-4, 220-5, 220-6). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 5 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Relay (RY1) 6 Select the Operation Check Mode, and then change the signal of the following signal to “H”. Device Code : 22 (Fuser Relay) And check the resistance between the following points. Between RY1-2 and RY1-4 Between RY1-6 and RY1-8 Is the each resistance almost 0 ohm? No Replace the Relay. Solid State Relay (SSR1) 7 Select the Operation Check Mode, and then change the signal of the following signals to “H”. Device Code : 22 (Fuser Relay) 21 (Fuser Lamp 1) Then check the voltage between J600 and J601. Is it 0V? CAUTION: Change the signal of “21” (Fuser Lamp 1) to “L” after checking! Yes Replace the Solid State Relay No Replace the PW11720 PCB.
  • Code: E-0003
  • Description: Fuser Temperature Abnormal Fall Error
    The difference of temperature between center and side of fuser becomes 50C or more.
  • Remedy: Error clearance 1 Have you cleared the fuser error in the Special Operation Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Special Operation Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Thermistors (TH1 & TH2) 3 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor.
  • Code: E-0004
  • Description: Fuser Temperature Abnormal Fall Error
    The Lamp of fuser lights (Signal HEAT1 is “H”) to heat up the Fuser Roller in the ready condition, but even 1C of temperature rise can not be accomplished within 30 seconds.
  • Remedy: Error clearance 1 Have you cleared the fuser error in the Special Operation Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Special Operation Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Lamp (H1) 3 Unplug the machine, and then check the resistance of Lamp (H1) with the multimeter. Is it 15k ohm or lower? No Replace the Lamp. Thermistors (TH1 & TH2) 4 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-4, 220-5, 220-6). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 5 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Relay (RY1) 6 Select the Operation Check Mode, and then change the signal of the following signal to “H”. Device Code : 22 (Fuser Relay) And check the resistance between the following points. Between RY1-2 and RY1-4 Between RY1-6 and RY1-8 Is the each resistance almost 0 ohm? No Replace the Relay. Solid State Relay (SSR1) 7 Select the Operation Check Mode, and then change the signal of the following signals to “H”. Device Code : 22 (Fuser Relay) 21 (Fuser Lamp 1) Then check the voltage between J600 and J601. Is it 0V? CAUTION: Change the signal of “21” (Fuser Lamp 1) to “L” after checking! Yes Replace the Solid State Relay No Replace the PW11720 PCB.
  • Code: E-0005
  • Description: Fuse Error
    Fuse (F1) is broken.
  • Remedy: Wires 1 Is the wire between the Fuse and PW11720 PCB connected properly? No Connect it properly. DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned OFF, and then check the Fuse. Is it OK? No Replace the Fuse with a new one. 3 Confirm that the machine is turned on, and then check the voltage of the orange line (J220-5). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires.
  • Code: E-0010
  • Description: Main Motor Error
    The Main Motor Output Detection Signal (MAINM_LD) continues to be “H” for 3 seconds or longer when the Main Motor is rotating.
  • Remedy: Wires 1 Is the wire between Main Motor and PW11720 PCB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-5). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Main Motor (M1) 3 Check the operation of Main Motor in the Operation Check Mode of the Service Mode. Device Code : 00 (Main Motor) Does the Main Motor operate correctly? No Replace the Main Motor.
  • Code: E-0013
  • Description: Paper Tray Motor Error
    The Paper Tray Motor Output Detection Signal (CSETM_LD) continues to be “H” for 3 seconds or longer when the Paper Tray Motor is rotating.
  • Remedy: Wires 1 Is the wire between Paper Tray Motor and PW11720 PCB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line. Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Paper Tray Motor (M3) 3 Check the operation of Main Motor in the Operation Check Mode of the Service Mode. Device Code : 33 (Paper Tray Motor) Does the Main Motor operate correctly? No Replace the Main Motor.
  • Code: E-0020
  • Description: Counter Error
    The Counter Connection Detection Signal (COUNT_OPN) continues to be “L” for 1 second or longer after turning on.
  • Remedy: Service Mode 1 Has the setting of Adjustment Mode Item No.753 set to “1” ? Yes Set it to “0”.
  • Code: E-0031
  • Description: Image Corona Output Error
    The Image Corona Output Detection Signal (IM_LD) continues to be “L” for 1 second or longer when the Image Corona is ON.
  • Remedy: Wire 1 Are wires among Image Corona, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. 2 (For Image Corona / Cleaning Roller only) Is the spring on the left bottom of the Process Unit OK? No Correct it properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 3 Is the Corona Wire broken? Yes Replace the Corona Wire. Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Cleaning Roller 4 Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 5 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 6 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 7 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-0032
  • Description: Separation Corona Output Error
    The Separation Corona Output Detection Signal (AC_LD) continues to be “L” for 1 second or longer when the Separation Corona is ON.
  • Remedy: Wire 1 Are wires among Image Corona, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. 2 (For Image Corona / Cleaning Roller only) Is the spring on the left bottom of the Process Unit OK? No Correct it properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 3 Is the Corona Wire broken? Yes Replace the Corona Wire. Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Cleaning Roller 4 Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 5 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 6 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 7 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-0033
  • Description: Transfer Corona Output Error
    The Transfer Corona Output Detection Signal (TR_LD) continues to be “L” for 1 second or longer when the Transfer Corona is ON.
  • Remedy: Wire 1 Are wires among Image Corona, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. 2 (For Image Corona / Cleaning Roller only) Is the spring on the left bottom of the Process Unit OK? No Correct it properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 3 Is the Corona Wire broken? Yes Replace the Corona Wire. Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Cleaning Roller 4 Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 5 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 6 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 7 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-0034
  • Description: Bias Output Error
    Bias Output Detection Signal (BIAS_LD) continues to be “L” for 1 second or longer when a specified bias is supplied to the corresponding Developer Unit components.
  • Remedy: Wires 1 Are wires among Developer Unit, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. Is the toner spill out from the Developer Unit? (Or is there any similar problem?) Yes Clean each Corona Wire, Grid Plate and housing. Developer Unit 2 Is the high voltage of Regulation Roller leaking? (The resistance between the central part of Regulation Roller and the Ground is 5 mega ohm or smaller if leaking.) Yes Replace the Regulation Roller. HV Power Supply 3 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-0040
  • Description: Cutter Error
    1. The Cutter Home Sensor Signal (MSCUT_L or MSCUT_R) does not change to “H” within 100 millisecond since the Cutter has started the operation.
    2. The Cutter Home Sensor Signal (MSCUT_L or MSCUT_R) does not change to “L” within 1 second since the Cutter has started the operation.
  • Remedy: Wires 1 Is the wire between Cutter Unit and PW11720 PCB connected properly? No Connect it properly. Cutter Home Position Sensors (MS8 & MS9) 2 Check the status of the following signals in the Signal Status Mode of the Service Mode. Signal Code : 094 (Cutter Home Position Right) 095 (Cutter Home Position Left) Is the status “L” when the Cutter is at each home position? No Replace the Cutter Unit. Cutter Motor (M4) 3 Check the operation of Cutter in the Operation Check Mode of the Service Mode. Device Code : 27 (Cutter Motor 1) 28 (Cutter Motor 2) Does the Cutter operate? No Replace the Cutter Unit.
  • Code: E-0050
  • Description: FPGA Error
    Initialization of FPGA is failed after turning on.
  • Remedy: PW11720 PCB 1 Can you fix the problem if you replace the PW11720 PCB? Yes OK
  • Code: E-0070
  • Description: Developer Error
    1. The Connector J-253 is not connected.
    2. The Switch (MS4) is “open” condition, which detects open/close of Engine Unit or Toner Hatch.
  • Remedy: Wires 1 Is the wire between Developer Unit and PW11720 PCB connected properly? No Connect it properly.
  • Code: E-0080
  • Description: Density Sensor Error
    Density Sensor cannot be calibrated correctly before Density Measure.
  • Remedy: Wires 1 Is the wire between Toner Density Sensor and PW11720 PCB connected properly? No Connect it properly. Density Sensor (PH8) 2 Can you fix the problem if you replace Density Sensor? No Replace PW11720 with a new one.
  • Code: E-0081
  • Description: Density Sensor Error
    Density Sensor cannot be calibrated correctly before Density Measure.
  • Remedy: Wires 1 Is the wire between Toner Density Sensor and PW11720 PCB connected properly? No Connect it properly. Density Sensor (PH8) 2 Can you fix the problem if you replace Density Sensor? No Replace PW11720 with a new one.
  • Code: E-0090
  • Description: Eraser Lamp Error
    1. The connector J-227 / J-228 is not connected.
    2. Eraser Lamp (PW6631) is broken.
  • Remedy: Wires 1 Is the wire between Toner Density Sensor and PW11720 PCB connected properly? Is the spring on the left bottom of the Process Unit OK? No Connect it properly. Eraser Lamp 2 Can you fix the problem if you replace the Process Unit? No Replace PW11720 with a new one.
Free Download WordPress Themes
Premium WordPress Themes Download
Download WordPress Themes Free
Download Nulled WordPress Themes
udemy paid course free download
download mobile firmware
Premium WordPress Themes Download
online free course
© Все права защищены, 2024

Мы позвоним Вам по указанному номеру телефона в ближайшее время.

Нажав кнопку сделать заказ сейчас, Вы подтверждаете свое согласие на обработку персональтныйх данных
Ваша заявка принята
Мы свяжемся с вами в ближайшее время