  • Code: E-000
  • Description: Fuser Temperature Rising Error
    Fuser Temperature does not reach 50C within 120 seconds after turning on.
  • Remedy: Error clearance 1 Have you cleared the fuser error in the Error Clear Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Error Clear Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1, H2), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Lamp (H1, H2) 3 Unplug the machine, and then check the resistance of Lamp (H1, H2) with the multi-meter. Is it 15k ohm or lower? No Replace the Lamp. Thermistors (TH1 & TH2) 4 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-4). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 5 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Relay (RY1) 6 Select the Device Operation Mode, and then change the signal of the following signal to “H”. Device Code : 22 (Fuser Relay) And check the resistance between the following points. Between RY1-2 and RY1-4 Between RY1-6 and RY1-8 Is the each resistance almost 0 ohm? No Replace the Relay Solid State Relay (SSR1) 7 Select the Device Operation Mode, and then change the signal of the following signals to “H”. Device Code : 22 (Fuser Relay) 21 (Fuser Lamp 1) Then check the voltage between J105-1 and J105-2. Is it 0V? CAUTION Change the signal of “21” (Fuser Lamp 1) to “L” after checking! Yes Replace the Solid State Relay No Replace the PW12420 PCB.
  • Code: E-001
  • Description: Fuser Over Temperature Error
    Fuser Temperature reaches over 230C.
  • Remedy: Error clearance 1 Have you cleared the fuser error in the Error Clear Mode? (Refer to the page 8-154 as for the Error Clear Mode.) Yes Wait until the Fuser Unit is enough cooled down. Then select the Error Clear Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1, H2), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Solid State Relay (SSR1) 3 Does the error occur again even if you have cleared it in the Error Clear Mode? Yes Replace the Solid State Relay. Thermistors (TH1 & TH2) 4 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor.
  • Code: E-002
  • Description: Fuser Low Temperature Error
    1. Fuser Temperature at the time of turning on was 50 to 100C, but it does not rise up to 120C within 150 seconds after that.
    2. Fuser Temperature at the time of turning on was higher than 100C, but it does not rise up to the setting temperature within 330 seconds after that.
  • Remedy: Error clearance 1 Have you cleared the fuser error in the Error Clear Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Error Clear Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1, H2), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Lamp (H1, H2) 3 Unplug the machine, and then check the resistance of Lamp (H1, H2) with the multi-meter. Is it 15k ohm or lower? No Replace the Lamp. Thermistors (TH1 & TH2) 4 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-4). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 5 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Relay (RY1) 6 Select the Device Operation Mode, and then change the signal of the following signal to “H”. Device Code : 22 (Fuser Relay) And check the resistance between the following points. Between RY1-2 and RY1-4 Between RY1-6 and RY1-8 Is the each resistance almost 0 ohm? No Replace the Relay Solid State Relay (SSR1) 7 Select the Device Operation Mode, and then change the signal of the following signals to “H”. Device Code : 22 (Fuser Relay) 21 (Fuser Lamp 1) Then check the voltage between J105-1 and J105-2. Is it 0V? CAUTION Change the signal of “21” (Fuser Lamp 1) to “L” after checking! Yes Replace the Solid State Relay No Replace the PW12420 PCB.
  • Code: E-003
  • Description: Fuser Temperature Abnormal Fall Error
    The difference of temperature between center and side of fuser becomes 50C or more.
  • Remedy: Error clearance 1 Have you cleared the fuser error in the Error Clear Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Error Clear Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1, H2), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Thermistors (TH1 & TH2) 3 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor.
  • Code: E-004
  • Description: Fuser Temperature Abnormal Fall Error
    The Lamp of fuser lights (Signal HEAT1 is “H”) to heat up the Fuser Roller in the ready condition, but even 1C of temperature rise can not be accomplished within 30 seconds.
  • Remedy: Error clearance 1 Have you cleared the fuser error in the Error Clear Mode? Yes Wait until the Fuser Unit is enough cooled down. Then select the Error Clear Mode and clear the concerning error. Wires 2 Are wires among Lamp (H1, H2), Solid State Relay (SSR1) and Thermistors (TH1 & TH2) connected properly? No Connect them properly. Lamp (H1, H2) 3 Unplug the machine, and then check the resistance of Lamp (H1, H2) with the multi-meter. Is it 15k ohm or lower? No Replace the Lamp. Thermistors (TH1 & TH2) 4 Select the Information Mode, and then check the temperature of fuser detected by Thermistors (TH1 & TH2). Item No. : 00 (Fuser temperature 1) 01 (Fuser temperature 2) Is each temperature normal? No Replace the concerning Thermistor. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-4). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 5 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Relay (RY1) 6 Select the Device Operation Mode, and then change the signal of the following signal to “H”. Device Code : 22 (Fuser Relay) And check the resistance between the following points. Between RY1-2 and RY1-4 Between RY1-6 and RY1-8 Is the each resistance almost 0 ohm? No Replace the Relay Solid State Relay (SSR1) 7 Select the Device Operation Mode, and then change the signal of the following signals to “H”. Device Code : 22 (Fuser Relay) 21 (Fuser Lamp 1) Then check the voltage between J105-1 and J105-2. Is it 0V? CAUTION Change the signal of “21” (Fuser Lamp 1) to “L” after checking! Yes Replace the Solid State Relay No Replace the PW12420 PCB.
  • Code: E-010
  • Description: Main Motor Error
    The Main Motor Output Detection Signal (MAINM_LD) continues to be “H” for 3 seconds or longer when the Main Motor is rotating.
  • Remedy: Wires 1 Is the wire between Main Motor and PW12420 PCB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-4). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Main Motor (M1) 3 Check the operation of Main Motor in the Device Operation Mode of the Service Mode. Device Code : 00 (Main Motor) Does the Main Motor operate correctly? No Replace the Main Motor.
  • Code: E-011
  • Description: Fuser Motor Error
    The Fuser Motor Output Detection Signal (HEATM_LD) continues to be “H” for 3 seconds or longer when the Fuser Motor is rotating.
  • Remedy: Wires 1 Is the wire between Fuser Motor and PW12420 PCB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-4). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse. Fuser Motor (M2) 3 Check the operation of Fuser Motor in the Device Operation Mode of the Service Mode. Device Code : 01 (Fuser Motor) Does the Fuser Motor operate correctly? No Replace the Fuser Motor.
  • Code: E-012
  • Description: Developer Press Motor Error
    The Developer Press Sensor Signal (PRESS_S) does not change to “L” within 30 seconds after turning on.
  • Remedy: Wires 1 Are the wires among Developer Press Sensor (PH4), PW12420 PCB, Driver PCB B (PW6654) and Developer Press Motor (M4) connected properly? No Connect them properly. Developer Press Motor (M4) Driver PCB B (PW6654) 2 Turn off the machine, and then turn it on again. Is the Developer Unit moved to the Drum side? No Replace the Developer Press Motor or Driver PCB B. Developer Press Sensor (PH4) 3 Select the Signal Code “104” (Developer Press Sensor) in the Signal Status Mode, and then turn on the machine again. Does the status change from “H” to “L” after turning on? No Replace the Developer Press Sensor. Fuse 4 Does the fuse (F3) have a proper conductivity? No Replace the fuse (F3).
  • Code: E-020
  • Description: Counter Error
    The Counter Connection Detection Signal (COUNT_OPN) continues to be “L” for 1 second or longer after turning on.
  • Remedy: Wires 1 Is the wire between Counter and PW12420 PCB connected properly? No Connect it properly. Confirm that the machine is turned on, and then check the voltage of the orange line (J220-5). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. DC Power Supply (DCP1) or Fuse 2 Turn off the machine. Does the fuse (F1) have a proper conductivity? No Replace the fuse (F1). Counter 3 Check the operation of Counter in the Device Operation Mode of the Service Mode. Device Code : 26 (Counter) Does the Counter operate correctly? No Replace the Counter.
  • Code: E-031
  • Description: Image Corona Output Error
    The Image Corona Output Detection Signal (IM_LD) continues to be “L” for 1 second or longer when the Image Corona is ON.
  • Remedy: Wires 1 Are wires among Image Corona, HV Power Supply PCB and PW12420 PCB connected properly? No Connect them properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 2 Is the Corona Wire broken? Yes Replace the Corona Wire. Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Cleaning Roller 3 Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 4 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 5 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 6 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-032
  • Description: Separation Corona Output Error
    The Separation Corona Output Detection Signal (AC_LD) continues to be “L” for 1 second or longer when the Separation Corona is ON.
  • Remedy: Wires 1 Are wires among Image Corona, HV Power Supply PCB and PW12420 PCB connected properly? No Connect them properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 2 Is the Corona Wire broken? Yes Replace the Corona Wire. Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Cleaning Roller 3 Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 4 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 5 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 6 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-033
  • Description: Transfer Corona Output Error
    The Transfer Corona Output Detection Signal (TR_LD) continues to be “L” for 1 second or longer when the Transfer Corona is ON.
  • Remedy: Wires 1 Are wires among Image Corona, HV Power Supply PCB and PW12420 PCB connected properly? No Connect them properly. Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Image Corona 2 Is the Corona Wire broken? Yes Replace the Corona Wire. Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Cleaning Roller 3 Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft. Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Transfer Corona 4 Is the Corona Wire broken? Yes Replace the Corona Wire. Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Separation Corona 5 Is the Corona Wire broken? Yes Replace the Corona Wire. HV Power Supply 6 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-034
  • Description: Bias Output Error
    Bias Output Detection Signal (BIAS_LD) continues to be “L” for 1 second or longer when a specified bias is supplied to the corresponding Developer Unit components.
  • Remedy: Wires 1 Are wires among Developer Unit, HV Power Supply PCB and PW12420 PCB connected properly? No Connect them properly. Is the toner spill out from the Developer Unit? (Or is there any similar problem?) Yes Clean each Corona Wire, Grid Plate and housing. Developer Unit 2 Is the high voltage of Regulation Roller leaking? (The resistance between the central part of Regulation Roller and the Ground is 5 mega ohm or smaller if leaking.) Yes Replace the Regulation Roller. HV Power Supply 3 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-040
  • Description: Cutter Error
    1. The Cutter Home Sensor Signal (MSCUT_L or MSCUT_R) does not change to “H” within 100 millisecond since the Cutter has started the operation.
    2. The Cutter Home Sensor Signal (MSCUT_L or MSCUT_R) does not change to “L” within 1 second since the Cutter has started the operation.
  • Remedy: Wires 1 Is the wire between Cutter Unit and PW12420 PCB connected properly? No Connect it properly. Cutter Home Position Sensors (MS6 & MS7) 2 Check the status of the following signals in the Signal Status Mode of the Service Mode. Signal Code : 094 (Cutter Home Position Right) 095 (Cutter Home Position Left) Is the status “L” when the Cutter is at each home position? No Replace the Cutter Unit. Developer Press Sensor (PH4) 3 Check the operation of Cutter in the Device Operation Mode of the Service Mode. Device Code : 27 (Cutter Motor 1) 28 (Cutter Motor 2) Does the Cutter operate? No Replace the Cutter Unit.
  • Code: E-050
  • Description: FPGA Error
    Initialization of FPGA is failed after turning on.
  • Remedy: PW12420 PCB 1 Can you fix the problem if you replace the PW12420 PCB? Yes OK
  • Code: E-070
  • Description: Developer Unit Set Error
    1. The Connector J-253 is not connected.
    2. The Switch (MS4) is “open” condition, which detects open/close of Engine Unit or Toner Hatch.
  • Remedy: Wires 1 Is the wire between Developer Unit and PW12420 PCB connected properly? No Connect it properly. Switch (MS4) 2 Is the actuator of Switch correctly pressed down when you close the Engine Unit or Toner Hatch? No Adjust the positions of Switch (or Toner Hatch and Engine Unit).
  • Code: E-080
  • Description: Density Sensor Error
    The default output of Density Sensor reaches less than 0.1V or more than 1.3V.
  • Remedy: Wires 1 Is the wire between Toner Density Sensor and PW12420 PCB connected properly? No Connect it properly. Density Sensor (PH11) 2 Can you fix the problem if you replace Density Sensor? No Replace PW12420 with a new one.
  • Code: E-081
  • Description: Density Sensor Output Error
    The gap between the default output and the standard output of Density Sensor reaches less than 2V.
  • Remedy: Wires 1 Is the wire between Toner Density Sensor and PW12420 PCB connected properly? No Connect it properly. Density Sensor (PH11) 2 Can you fix the problem if you replace Density Sensor? No Replace PW12420 with a new one.
Premium WordPress Themes Download
Download WordPress Themes
Download Premium WordPress Themes Free
Download WordPress Themes Free
udemy paid course free download
download lava firmware
Premium WordPress Themes Download
free online course
© Все права защищены, 2024

Мы позвоним Вам по указанному номеру телефона в ближайшее время.

Нажав кнопку сделать заказ сейчас, Вы подтверждаете свое согласие на обработку персональтныйх данных
Ваша заявка принята
Мы свяжемся с вами в ближайшее время